Parameter reference

15.2

Parameter list | C00003

752

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3900674 Device command in process

59:

Resolver error identification

3866624 Device command executed successfully
3866625 General error
3906358 Resolver error identification cannot be executed since

the wrong control type is active (no servo control).

3906359 Resolver error identification cannot be executed since an

error or trouble is active.

3906360 Resolver error identification cannot be executed because

another identification is already active.

3906361 Resolver error identification cannot be executed because

of too small speed (< 500 rpm).

4587520 Device command executed successfully

70:

Load Lenze INV characteristic

4587521 General error
4621570 Device command in process
4653056 Device command executed successfully

71:

Calculate inv. characteristic

4653057 General error
4687106 Device command in process
4692754 The calculation of the inverter characteristic cannot be

started since the current controller test mode is active.

4692755 The calculation of the inverter characteristic cannot be

started since the V/f test mode is active.

4692756 The calculation of the inverter characteristic cannot be

started since the pole position identification is active.

4692757 Calculation of the inverter characteristic has been

aborted.

4692758 Calculation of the inverter characteristic has been

interrupted by error.

4692789 Detected inverter error characteristic exceeds internal

limits. This situation can for instance occur if the motor

power is very much lower than the device power.

4718592 Device command executed successfully

72:

Determine motor parameters

4718593 General error
4752642 Device command in process
4758290 Motor identification cannot be started since the current

controller test mode is active.

4758291 Motor identification cannot be started since the V/f test

mode is active.

4758292 Motor identification cannot be started because pole

position identification is active.

4758293 Motor identification has been aborted.
4758294 Motor identification has been aborted by fault.
4758332 Motor identification aborted due to inconsistent motor

parameters.

5046272 Device command executed successfully

77:

Calculate current controller

parameters

5046273 General error
5080322 Device command in process
5086002 At least one calculated value is outside the valid setting

range.

5086003 Stator resistance (

C00084

) too small (zero).

Status

Meaning

Device command