C00810 | mctrl_dnspeedctrladapt, C00811 | mctrl_dnposctrladapt, C00812 | mctrl_dnmotorposrefvalue – Lenze E94AxPExxxx User Manual
Page 843: C00813 | mctrl_dnloadposrefvalue, C00814 | mctrl_dnboost, 15 parameter reference

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
843
15
Parameter reference
15.2
Parameter list | C00810
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00810
C00811
C00812
C00813
C00814
Parameter | Name:
C00810 | MCTRL_dnSpeedCtrlAdapt
Data type: INTEGER_32
Index: 23765
d
= 5CD5
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-200.00
%
200.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00811 | MCTRL_dnPosCtrlAdapt
Data type: INTEGER_32
Index: 23764
d
= 5CD4
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-200.00
%
200.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00812 | MCTRL_dnMotorPosRefValue
Data type: UNSIGNED_32
Index: 23763
d
= 5CD3
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0
Incr.
4294967295
Subcodes
Info
C00812/1
LOW word
C00812/2
High word
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00813 | MCTRL_dnLoadPosRefValue
Data type: UNSIGNED_32
Index: 23762
d
= 5CD2
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0
Incr.
4294967295
Subcodes
Info
C00813/1
LOW word
C00813/2
High word
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00814 | MCTRL_dnBoost
Data type: INTEGER_32
Index: 23761
d
= 5CD1
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-1000
V
1000
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1