303 Archive parameter set 3
Saves the current parameter set as parameter set 3 in the
memory module.
304 Archive parameter set 4
Saves the current parameter set as parameter set 4 in the
memory module.
401 Internal command 401
For Lenze service only
501 Load cam data
Reloads cam data from the memory module into the
controller.
• Only possible when the application has stopped and
the controller is inhibited.
• If the cam data are provided with an access
protection, the user password has to be entered in
first.
Basic function "
"
502 Save cam data
Saves the cam data available in the main memory of the
controller in the memory module with mains failure
protection.
• If the cam data are provided with an access
protection, the user password has to be entered in
first.
Basic function "
"
503 Calculate cam data
Converts the cam data available in the main memory of
the controller into the internal format and provides them
to the application.
Basic function "
"
504 Calculate cam data checksum
Recalculates the checksum of the cam data available in
the main memory of the controller.
• Required if the cam data in the main memory of the
controller have been changed via parameters.
Basic function "
"
730 Internal command 730
For Lenze service only
731 Internal command 731
For Lenze service only
732 Internal command 732
For Lenze service only
733 Internal command 733
For Lenze service only
800 Internal command 800
For Lenze service only
810 Internal command 810
811 Internal command 811
812 Internal command 812
1001 Internal command 1001
For Lenze service only
1020 Internal command 1020
For Lenze service only
1021 Export parameters to file
For Lenze service only
1030 Format file system
Formats file system of the memory module.
1040 Restore file system
Restores file system of the memory module (low level
formatting).
• The low level formatting of the file system by the user
is only intended for the exceptional case when the
standard formatting is not possible anymore, e.g. due
to damaged internal management information.
10000 Prepare firmware update
Sets the controller to the firmware update mode.
11000 Restart controller
Restarts controller via parameter setting.
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00002 | Device command