C00050 | speed setpoint [rpm, C00051 | actual speed [rpm, C00052 | motor voltage – Lenze E94AxPExxxx User Manual
Page 760: C00053 | dc-bus voltage, C00054 | motor current, C00052, C00054, Rrent displayed in, With t, Corresponds

15
Parameter reference
15.2
Parameter list | C00050
760
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00050
C00051
C00052
C00053
C00054
Parameter | Name:
C00050 | Speed setpoint [rpm]
Data type: INTEGER_32
Index: 24525
d
= 5FCD
h
Display range
(min. value | unit | max. value)
-480000
rpm
480000
Subcodes
Info
C00050/1
Speed setpoint 1 [rpm]
C00050/2
Speed setpoint 2 [rpm]
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00051 | Actual speed [rpm]
Data type: INTEGER_32
Index: 24524
d
= 5FCC
h
Display range
(min. value | unit | max. value)
-480000
rpm
480000
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00052 | Motor voltage
Data type: UNSIGNED_32
Index: 24523
d
= 5FCB
h
Display range
(min. value | unit | max. value)
0
V
2147483647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00053 | DC-bus voltage
Data type: UNSIGNED_32
Index: 24522
d
= 5FCA
h
Display range
(min. value | unit | max. value)
0
V
2147483647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00054 | Motor current
Data type: UNSIGNED_32
Index: 24521
d
= 5FC9
h
Display range
(min. value | unit | max. value)
0.00
A
500.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100