C00174 | undervoltage (lu) threshold, C00178 | elapsed-hour meter, C00179 | power-on time meter – Lenze E94AxPExxxx User Manual
Page 778: C00180 | service code, C00174, C00600, C00178, C00179, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00174
778
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00174
C00175
C00176
C00177
C00178
C00179
C00180
Parameter | Name:
C00174 | Undervoltage (LU) threshold
Data type: UNSIGNED_32
Index: 24401
d
= 5F51
h
Setting range
(min. value | unit | max. value)
Lenze setting
15
V
400 285 V
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00175 | Service code
Data type: UNSIGNED_32
Index: 24400
d
= 5F50
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00176 | Service code
Data type: UNSIGNED_32
Index: 24399
d
= 5F4F
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00177 | Service code
Data type: UNSIGNED_32
Index: 24398
d
= 5F4E
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00178 | Elapsed-hour meter
Data type: UNSIGNED_32
Index: 24397
d
= 5F4D
h
Display range
(min. value | unit | max. value)
0
s
4294967295
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00179 | Power-on time meter
Data type: UNSIGNED_32
Index: 24396
d
= 5F4C
h
Display range
(min. value | unit | max. value)
0
s
4294967295
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00180 | Service code
Data type: VISIBLE_STRING
Index: 24395
d
= 5F4B
h
For Lenze service only
Read access Write access CINH PLC STOP No transfer
Character length: 192