1 response, 2 instance id, Response – Lenze E94AxPExxxx User Manual
Page 643: Instance id, 14 diagnostics & fault analysis

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
643
14
Diagnostics & fault analysis
14.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.7.1.1
Response
The state of the internal device control changes according to the selected response to an error,
controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes on:
14.7.1.2
Instance ID
The instance ID is dynamically assigned by the operating system.
Bit 31
Bit 30
Bit 29
Response
0
0
0
0: No response
0
0
1
1: Fault
0
1
0
2: Trouble
0
1
1
3: Quick stop by trouble
1
0
0
4: Warning locked
1
0
1
5: Warning
1
1
0
6: Information
1
1
1
7: System fault
Response
Logbook entry
Display in
Disable voltage
Disable drive
function
Acknowledgeme
nt required
LED
"DRIVE ERROR"
None
OFF
Information
OFF
Warning
Warning locked
Quick stop by
trouble
Trouble
(after 0.5 s)
Fault
System fault
Mains
switching
is required!
Bit 31
16
25
26
28
29
0
15
Bit 28
Bit 27
Bit 26
Meaning
0
0
0
Instance ID 0
0
0
1
Instance ID 1
0
1
0
Instance ID 2
0
1
1
Instance ID 3
1
0
0
Instance ID 4
1
0
1
Instance ID 5
1
1
0
Instance ID 6
1
1
1
Instance ID 7
Bit 31
16
25
26
28
29
0
15