C00990 | flying restart: activation, C00991 | flying restart: current, C00992 | flying restart: start frequency – Lenze E94AxPExxxx User Manual
Page 853: C00993 | flying restart: integration time, C00994 | flying restart: min. deviation, C00990, D in, C00991, C00992, C00993
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
853
15
Parameter reference
15.2
Parameter list | C00990
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00990
C00991
C00992
C00993
C00994
Parameter | Name:
C00990 | Flying restart: Activation
Data type: UNSIGNED_32
Index: 23585
d
= 5C21
h
Note!
Only deactivate the flying restart for the V/f control or sensorless vector control if it is ensured that the drive is
always at standstill in the case of controller enable!
Selection list
(Lenze setting printed in bold)
0 Off
1 On
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00991 | Flying restart: Current
Data type: INTEGER_32
Index: 23584
d
= 5C20
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 15 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00992 | Flying restart: Start frequency
Data type: INTEGER_32
Index: 23583
d
= 5C1F
h
Setting range
(min. value | unit | max. value)
Lenze setting
-600.0
Hz
600.0 20.0 Hz
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00993 | Flying restart: Integration time
Data type: UNSIGNED_32
Index: 23582
d
= 5C1E
h
Setting range
(min. value | unit | max. value)
Lenze setting
1
ms
6000 60 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00994 | Flying restart: Min. deviation
Data type: UNSIGNED_32
Index: 23581
d
= 5C1D
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
°
90.00 5.00 °
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100