C02530 | active function state, C02531 | gearbox factors (decimal), Yed in – Lenze E94AxPExxxx User Manual
Page 875: C02530, D; display in, C02531/3, C02531/2, The currently active fun, 15 parameter reference

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
875
15
Parameter reference
15.2
Parameter list | C02530
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02530
C02531
Parameter | Name:
C02530 | Active function state
Data type: INTEGER_32
Index: 22045
d
= 561D
h
Displays the basic drive function that currently controls the drive.
Selection list
(read only)
0 Program stopped
1 Initial/boot state active
2 Torque follower active
3 Speed follower active
4 Position follower active
5 Setpoint follower active
6 Positioning active
7 Homing active
8 Manual jog active
9 Brake test active
10 Drive at standstill
11 Drive is stopped
12 Quick stop active
13 Reserve 1
14 Controller is not ready
15 Initialisation
16 Fault
17 Manual control open loop active
18 Pole position identification active
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02531 | Gearbox factors (decimal)
Data type: UNSIGNED_32
Index: 22044
d
= 561C
h
Note: In subcode 3 the effective gearbox factor resulting form the motor and the load is displayed if a separate
position encoder is configured and the position control is activated (
="2"). For a different encoder
configuration (without a separate position encoder) the value "1" is shown in subcode 3.
Display range
(min. value | unit | max. value)
0.000
2147483.647
Subcodes
Info
C02531/1
Motor gearbox factor (dec.)
C02531/2
Pos. enc. gearbox factor (dec.)
C02531/3
Effective gearbox factor (dec.)
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000