895
15
Parameter reference
15.2
Parameter list | C02638
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02638
C02639
C02640
Parameter | Name:
C02638 | Manual jog: Status
Data type: INTEGER_32
Index: 21937
d
= 55B1
h
Status of the basic function "
".
Display range
(min. value | unit | max. value)
0
8
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02639 | Manual jog: Dig. signals
Data type: UNSIGNED_32
Index: 21936
d
= 55B0
h
Display of the digital signals of the basic function "
Selection list
(read only)
0 FALSE
1 TRUE
Subcodes
Info
C02639/1
MAN_bEnable
C02639/2
MAN_bJogPositive
C02639/3
MAN_bJogNegative
C02639/4
MAN_bActivateJogSpeed2
C02639/5
MAN_bReleaseLimitSwitch
C02639/6
MAN_bEnabled
C02639/7
MAN_bActive
C02639/8
MAN_bStepMode
C02639/9
MAN_bIntermediateStopMode
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02640 | Homing mode
Data type: UNSIGNED_32
Index: 21935
d
= 55AF
h
Selection of the homing mode.
Basic function "
Selection list
(Lenze setting printed in bold)
Info
0 cw_Rn_TP
Positive direction - via home mark - to TP
1 ccw_Rn_TP
Negative direction - via home mark - to TP
2 cw_Lp_ccw_Rn_TP
Pos. direction - reversing to limit switch - via home mark
- to TP
3 ccw_Ln_cw_Rn_TP
Neg. direction - reversing to limit switch - via home mark
- to TP
4 cw_Rp_ccw_Rn_TP
Pos. direction - reversing to home mark - to TP
5 ccw_Rp_cw_Rn_TP
Neg. direction - reversing to home mark - to TP