C01215 | set time and date, C01215, 15 parameter reference – Lenze E94AxPExxxx User Manual
Page 863

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
863
15
Parameter reference
15.2
Parameter list | C01215
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01215
C01217
C01218
C01220
C01221
Parameter | Name:
C01215 | Set time and date
Data type: UNSIGNED_16
Index: 23360
d
= 5B40
h
Setting of the system time of the controller displayed in
• If the MM440 memory module with real-time clock is plugged into the controller, the real-time clock is set
simultaneously.
Set time and date.
• Before writing to a subcode for the first time, the current time information according to the internal clock is
displayed in the subcodes.
• When a value has been written into a subcode, the displays in the subcodes freeze to the last values.
• The new system time set is only accepted after a value has been written into each subcode at least once.
• After the new system time has been accepted, the display in the subcodes is updated according to the internal
clock.
Note:
If a memory module without real-time clock is plugged into the controller, the internal clock is initialised with
"01.01.1970 00:00:00" every time the mains is switched on.
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C01215/1
0
Seconds
C01215/2
0
Minutes
C01215/3
0
Hours
C01215/4
1
Day
C01215/5
1
Month
C01215/6
1970
Year
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01217 | Service code
Data type: VISIBLE_STRING
Index: 23358
d
= 5B3E
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01218 | Service code
Data type: UNSIGNED_32
Index: 23357
d
= 5B3D
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01220 | MEC history: RAM address
Data type: UNSIGNED_32
Index: 23355
d
= 5B3B
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01221 | MEC history: RAM value
Data type: UNSIGNED_32
Index: 23354
d
= 5B3A
h
This code is for device-internal use only and must not be written to by the user!