5 inserting more user pous, Inserting more user pous, 4plc functionality – Lenze E94AxPExxxx User Manual
Page 46

4
PLC functionality
4.2
Preparations for creating a PLC program
46
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
List of the system events
• Execution of a maximum of 1,000 instructions as a result of a system event is permissible.
• POUs (= program organisation unit) which are called by system events are not monitored
according to runtimes by a "watchdog" compared to tasks.
4.2.5
Inserting more user POUs
Four POUs have already been created in the POUs
Standard project "PLC_Application.pro"
In order to insert more POUs, please select the menu command ProjectObjectInsert.
The New POU opens where you can define the type, name and language you want to use to program
the POU:
System event
The called POU starts, ...
PLC_AfterReset
after the PLC has been reset.
PLC_BeforeReset
before the PLC is reset.
PLC_DebugLoop
Not supported
PLC_FQSPState
when quick stop by trouble has been activated.
PLC_MessageState
when a message has been activated.
PLC_OnboardCANError
when a system bus error occurs (e.g. Bus-Off).
PLC_Start
when the PLC is started.
PLC_Stop
when the PLC is stopped.
PLC_TaskOverrun
when a task has overflown.
PLC_TripState
when trouble has been activated.
PLC_WarningState