beautypg.com

Can module (mxi2): bus off [0x00ac0000, 0x00ac0000, 0x00aa0003 – Lenze E94AxPExxxx User Manual

Page 724: 0x00aa0004, 0x00aa0005, 14 diagnostics & fault analysis

background image

14

Diagnostics & fault analysis

14.7

Error messages of the operating system

724

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DFIN (MXI2): Signal error enable/lamp control [0x00aa0003]

DFIN (MXI2): Supply cannot be corrected anymore [0x00aa0004]

DFOUT (MXI2): Maximum frequency reached [0x00aa0005]

CAN module (MXI2): Bus off [0x00ac0000]

Module ID (decimal)

Error ID (decimal)

170: Extension module - digital frequency in MXI2

3

Response (Lenze setting printed in bold)

Setting:

C14041

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Digital frequency extension module in MXI2:

Interruption (open circuit) of the signal cable for the

"Enable" signal or no "Enable" signal available.

• Check signal cable for "Enable" signal.

• Check encoder.

Module ID (decimal)

Error ID (decimal)

170: Extension module - digital frequency in MXI2

4

Response (Lenze setting printed in bold)

Setting:

C14042

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Digital frequency extension module in MXI2: The

encoder voltage controlled by the digital frequency input

has reached the voltage limit.

Check encoder.

Module ID (decimal)

Error ID (decimal)

170: Extension module - digital frequency in MXI2

5

Response (Lenze setting printed in bold)

Setting:

C14080

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Digital frequency extension module in MXI2: Limit

frequency at the digital frequency output reached.

• The digital frequency has reached the limit value set

in

C014053

.

Check limit value set.

Module ID (decimal)

Error ID (decimal)

172: CAN module in MXI2: CAN dispatcher

0

Response (Lenze setting printed in bold)

Setting:

C14595

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CANopen communication module in MXI2: "Bus-off"

state

• Received too many faulty telegrams.

• Defective cable (e.g. loose contact).

• Two nodes with the same ID.

• Remove fault (e.g. EMC).

• Remove loose contact, screw down adapter.

• Assign different IDs to nodes.