2 loading home position via input, 3 resetting home position, Loading home position via input – Lenze E94AxPExxxx User Manual
Page 508: Resetting home position, 12 basic drive functions

12
Basic drive functions
12.6
Homing
508
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.6.5.1
Starting reference search/setting the reference directly
By setting the HM_bActivateHoming control input to TRUE, the reference search in the selected
homing mode is started.
• During reference search, the HM_bActive status output is set to TRUE.
• By setting the status output HM_bHomePosAvailable to TRUE, it is already signalised during the
reference search that the home position has been found. Depending on the homing mode
selected, the drive traverses further on to the target position set in
• When the reference search is completed, the HM_bActive status output is reset to FALSE and the
HM_bDone status output is set to TRUE.
12.6.5.2
Loading home position via input
By setting the control input HM_bLoadHomePos to TRUE, the "Tool position" that is pending at input
HM_dnHomePos_p is manually accepted as home position during the drive is at standstill. This is
also possible if the controller is inhibited.
• The HM_bDone status output is set to TRUE for one cycle.
• The HM_bHomePosAvailable status output is set to TRUE.
12.6.5.3
Resetting home position
By setting the control input HM_bResetHomePos to TRUE, the "Home position known" status can be
reset.
• The status outputs HM_bDone and HM_bHomePosAvailable are reset to FALSE.
Note!
In the homing mode "100: Set reference directly" no reference search is started, but the
home position set in
is directly accepted.
Note!
The following applies to the encoderless motor control types :
If the V/f control or sensorless vector control is selected, this function can be activated
irrespective of the use of the position controller.
Note!
The following applies to the encoderless motor control types :
If the V/f control or sensorless vector control is selected, this function can be activated
irrespective of the use of the position controller.