Configuring radios in batches

To ease radio parameter configuration and reduce repetitive operations, WSM allows you to
configure public parameters for multiple radios of the fit APs managed by an AC in batches.

Parameters include the radio type, maximum transmit power, admin status, channel in use, operating

mode, description, and neighborhood scanning.
You can access the Radio Batch Configuration function from the AC List page, the AC details page, or
the configuration management page. The following information uses the AC List page as an example.
To configure radios in batches:

1.

Click the Service tab.
From the navigation tree, select WLAN Manager > Resource Management > ACs. The AC List
page displays all ACs.

2.

Click the Operation icon

for an AC.

3.

Select Radio Batch Configuration from the menu.
The page for configuring radios in batches appears.

4.

Select and set the parameters as needed.

{

Radio Type—Select a radio type from the list. Options are:

802.11a

802.11b

802.11g

802.11bg

802.11at

802.11an

802.11gn

802.11n (2.4GHz)

802.11bgn

802.11n

802.11n(5GHz)

{

Max Transmission Power—Enter the maximum transmission power of the radio. The value
range depends on the device model. See the device manual for reference.

{

Admin Status—Select an administrative state for the radio. Options are Up and Down.

{

Channels in Use—Select the working channel of the radio. The value range depends on the
radio type. If you select Auto, a fit AP selects an idle channel as the working channel.

{

Operating Mode—Select the operating mode of the radio. Options are:

Access Point and Local Mesh

Access Point Only

Local Mesh Only

Monitor

Sensor

The value range depends on the device model.

{

Description—Enter a description for the radio.