Configuring ac global parameters – H3C Technologies H3C Intelligent Management Center User Manual
Page 106

84
{
License Key—License key of a standard license. To get the license key, purchase the software
license certificate.
{
Activation Key—Activation key obtained by providing the license key, serial number, and
verification code of the device on the website.
{
AP Limit—Number of APs allowed by the license.
5.
Click Close.
Configuring AC global parameters
You can access the AC Parameter Configuration page from the AC details page or the configuration
management page. The following information uses the AC details page as an example.
To configure AC global parameters:
1.
Click the Service tab.
2.
From the navigation tree, select WLAN Manager > Resource Management > ACs. The AC List
page displays all ACs.
a.
Click the device label of the target AC.
b.
Click the Modify icon for the global parameter information.
Or
Click the Global Configuration link in the AC Configuration area to the right of the page.
The AC Global Parameter Configuration page appears.
3.
Set the following parameters as needed:
{
Load Balancing—Set whether to enable load balancing. Options are Traffic Threshold, Client
Count Threshold, and No Threshold.
−
If you select Traffic Threshold, traffic load balancing is enabled. Enter the traffic load
balancing threshold to control traffic at the wireless side for fit APs managed by the AC.
The value is the ratio of traffic at the wireless side of a fit AP to the throughput of the AP
expressed in percentage. When the traffic of any fit AP managed by the AC reaches the
threshold, the fit AP rejects requests from any client and the AC informs another fit AP to
accept those requests.
−
If you select Client Count Threshold, client load balancing is enabled. Enter the client
load balancing threshold to control client traffic for fit APs managed by the AC. When
the number of clients associated to any fit AP managed by the AC reaches the threshold,
the fit AP rejects requests from any client and the AC informs another fit AP to accept
those requests.
−
If you select No Threshold, load balancing is not enabled.
{
Auto AP—Select whether to enable the auto AP function. If you select Enable, the AC
automatically associates with the fit APs of the model specified in the template configured on
the AC. If you select Disable, the AC does not automatically associate with the fit APs even if
a template that contains the model is configured on the AC.
For more information about auto fit AP templates, see "
."
{
Scan Mode—Select the channel scanning mode. Options are Active and Passive. Active
indicates the fit APs operate as clients to send probe requests to other fit APs during the
scanning process. Passive indicates the fit APs do not send any probe requests during the
scanning process.