Metrohm 746 VA Trace Analyzer User Manual
Page 576

8.3 RS232 interfaces
746 VA Trace Analyzer / 747 VA Stand
8-15
746 VA Trace Analyzer as sender:
LF
DCD
CTS
TxD
DCD
CTS
TxD
DSR
DSR
RTS
RTS
DTR
DTR
The data flow can be interrupted by deactivation of the CTS line.
Software handshake with character stop (
SWchar
)
Handshake inputs are (CTS, DSR, DCD) are not checked at the 746 VA Trace Ana-
lyzer, handshake outputs (DTR, RTS) are set.
As soon as an LF is recognised, the 746 VA Trace Analyzer sends XOFF. After this
time, it can still receive 6 characters and store them temporarily.
However, the 746 VA Trace Analyzer also sends XOFF when its input buffer con-
tains 80 characters. After this time, it can still receive maximum 2 more characters
(incl. LF).
If the transmission is interrupted for 35 ms after the 746 VA Trace Analyzer has sent
XOFF, the string previously received will be processed even if no LF has been sent.
746 VA Trace Analyzer as receiver:
RxD
TxD
XOFF
XOFF
XON
L
F
External device
Gerät
400
µ
s
Process
string
Data
input
Data
output
35 ms
max. 2
char.
Time
80 characters
746
External device
746
Time
- 915 KF Ti-Touch (382 pages)
- 800 Dosino (53 pages)
- 767 Calibrated Reference (23 pages)
- 940 Professional IC Vario ONE/SeS/Prep 2 (54 pages)
- 754 Dialysis Unit (49 pages)
- 815 Robotic Soliprep for LC (76 pages)
- Vision Manual (207 pages)
- tiamo 2.1 Manual (1532 pages)
- 825 Lab Link (37 pages)
- 808 Titrando (70 pages)
- 902 Titrando (52 pages)
- 756 KF Coulometer (163 pages)
- 756 KF Coulometer (162 pages)
- 940 Professional IC Vario ONE/LPG (98 pages)
- 850 Professional IC Anion MCS Prep 3 (154 pages)
- 850 Professional IC Anion MCS Prep 3 (152 pages)
- 904 Titrando (58 pages)
- 850 Professional IC Anion MSM-HC MCS Prep 2 (150 pages)
- 930 Compact IC Flex Oven/ChS/Deg (47 pages)
- 872 Extension Module Liquid handling (64 pages)
- 814 USB Sample Processor (90 pages)
- 814 USB Sample Processor (91 pages)
- 940 Professional IC Vario (43 pages)
- Vision – Tutorial (40 pages)
- 799 GPT Titrino (242 pages)
- 889 IC Sample Center (68 pages)
- 761 Compact IC (228 pages)
- 851 Titrando (100 pages)
- 748 DH Sample Changer (32 pages)
- 940 Professional IC Vario ONE/SeS/HPG (51 pages)
- 896 Professional Detector – Amperometry (62 pages)
- 877 Titrino plus (139 pages)
- 881 Compact IC pro – Anion (129 pages)
- 940 Professional IC Vario ONE/ChS/HPG (112 pages)
- 930 Compact IC Flex Deg (41 pages)
- 840 PC Control 5.0 / Touch Control (351 pages)
- 940 Professional IC Vario ONE/Prep 1 (45 pages)
- 776 Dosimat (42 pages)
- 717 Sample Changer (36 pages)
- 815 Robotic USB Sample Processor XL (113 pages)
- 815 Robotic USB Sample Processor XL (114 pages)
- 940 Professional IC Vario ONE/SeS/PP (126 pages)
- 838 Advanced Sample Processor Installation Instructions (109 pages)
- 700 Dosino (55 pages)
- 719 S Titrino (152 pages)