beautypg.com

252 pdos>m, O, s, M, a – Metrohm 746 VA Trace Analyzer User Manual

Page 403

background image

5.7 Program instructions

746 VA Trace Analyzer / 747 VA Stand

5-252

PDOS>M

Page:

O, S

Stand:

M, A

Abbreviation:

PD

Instructions t/s Main parameters Auxiliary parameters

––––––––––––– ––––– ––––––––––––––––––––––––– –––––––––––––––––––––––––

## .. PDOS>M ..... Soln.name ........ Prop.coeff. ........

Prop.subst. ........

Function

Dispense auxiliary solution proportional to the measured evaluation value

EV:

of a substance into the measuring vessel (MEAS).

Parameter

Range; Default value / Meaning

Soln.name

8 characters; -

Name of the auxiliary solution

The entry of a solution name is mandatory when the auxiliary solution
should be added automatically using a 685 Dosimat, a 700 Dosino or
the 695 Autosampler. In this case the solution name

Soln.name

must

be entered in the parameter of the same name on the "SOLUTIONS"
page and assigned a position

Pos.

(see section 5.3.4).

Without entry of a name for

Soln.name

in the

PDOS>M

instruction,

without entry of this name on the "SOLUTIONS" page or without a
position assignment, the auxiliary solution must be dispensed manually
or with the 6.5611.010 Pipetting equipment (the prompt

DOS

"Soln.name" "V.add" > M

then appears during the program run with

the calculated addition volume being displayed for

V.add

in

µ

L).

Prop.subst.

8 characters; -

Name of the reference substance for proportional dispensing

Here, the name of the substance whose evaluation value

EV:

(in A, W or s) is the basis for the proportional dispensing of an auxiliary
solution must be entered. This can be the analyte or one of the 7 other
possible substances.

The name of the substance must be identical to one of the substance
names entered on the "SUBSTANCES/Calibration" page (see section

5.6.3).

Prop.coeff.

0.0010...99999.9; 1

Proportionality coefficient

The proportionality coefficient defines the relation between the meas-
ured mean value of the evaluation value

EV:

and the addition

volume

V.add

:

V.add = EV: * Prop.coeff.

Depending on the unit of the evaluation value

EV:

(nA, nW

or s), the proportionality coefficient has the unit

µ

L/nA,

µ

L/nW or

µ

L/s

giving a calculated standard addition volume

V.add

in

µ

L.

Description

The

PDOS>M

instruction is used for the automatic or manual dispensing

of auxiliary solutions (e.g. supporting electrolyte, reagent solution) into
the measuring vessel (MEAS) on the 747 VA Stand. In contrast to the