5.6 Method Specifications

746 VA Trace Analyzer / 747 VA Stand

5-146

Parameter

Range; Default value / Meaning

Soln.name

8 characters;

Name of standard addition solution

The name of the standard addition solution must be identical with the
name entered under

Soln.name

with an ADD or PADD instruction.

If the standard addition solution has to be added automatically, this
solution must be entered on the "SOLUTIONS" page and assigned a
position

Pos.

(see section 5.3.4). The standard addition solutions

entered on the "SUBSTANCES" page can here be automatically
copied to the solution list with the softkey

.

XXXXXXXX

--------

If already standard addition solutions have been entered on the "OP.
SEQUENCE" page, these names are displayed on the softkeys and
can be incorporated directly.

Mass conc.

0.001...999.99 ng...kg/L;

Mass concentration

ρρ

std

of standard addition solution

If the standard addition solution has to be added automatically, the
mass concentration must also be entered on the "SOLUTIONS" page
(see section 5.3.4).

Range min

0.001...999.99 ng...kg/L;

Lower limit of working range

Here, a lower limit can be optionally defined for the working range in
the standard addition. If a mass concentration

Mass conc.

less than

the value entered here is found for the substance, an error message is
put out and the remark

conc. out of range

displayed on the

"RESULTS" page.

The lower limit of the working range (in terms of the effective mass
concentration

ρ

eff

) is marked by a vertical line in the display and on the

plot of the calibration curve.

Range max

0.001...999.99 ng...kg/L;

Upper limit of working range

Here, an upper limit can be optionally defined for the working range in
the standard addition. If a mass concentration

Mass conc.

greater

than the value entered here is found for the substance, an error
message is put out and the remark

conc. out of range

displayed on

the "RESULTS" page.

The upper limit of the working range (in terms of the effective mass
concentration

ρ

eff

) is marked by a vertical line in the display and on the

plot of the calibration curve.

M.conc./cm

0.001...999.99 ng...kg/L;

Axis scaling for plot of standard addition curve

Here, the scale in g/L per cm for the plot of the x axis of the standard
addition curve (

ρ

eff

) can be entered. In the absence of an entry, the

entire curve is plotted within 10 cm.