Verifying the configuration, Client information backup configuration example, Network requirements – H3C Technologies H3C WX3000E Series Wireless Switches User Manual
Page 796
775
Figure 806 Backing up the IP address of AC 2
Verifying the configuration
1.
When AC 1 goes down, AC 3 becomes the new active AC.
2.
When AC 1 recovers, the AP connecting to AC 3 connects to AC 1 again. This is because the
highest AP connection priority of 7 on AC 1 ensures an automatic switchover.
Client information backup configuration example
Network requirements
As shown in
, AC 1 and AC 2 support stateful failover. AC 1 is the primary AC. Enable client
information backup on the two ACs so the clients can communicate during a primary/backup switchover.
The client in this example is a client that uses clear-type service template for accessing the network.
Figure 807 Network diagram
This manual is related to the following products:
- H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module