Configuring the nms, Verifying the configuration – H3C Technologies H3C WX3000E Series Wireless Switches User Manual
Page 170
149
b.
Select the destination IP address type as IPv4/Domain, enter the destination address 1.1.1.2,
enter the user name user1, select v3 from the Security Model list, and select Auth/Priv from the
Security Level list.
c.
Click Apply.
Figure 114 Adding target hosts of SNMP traps
Configuring the NMS
IMPORTANT:
The configuration on the NMS must be consistent with the configuration on the agent. Otherwise, you
cannot perform corresponding operations.
To configure the NMS:
1.
Specify the SNMPv3 version.
2.
Set the username to user1, authentication algorithm to MD5, authentication key to authkey,
encryption algorithm to DES56, and privacy key to prikey.
For more information about configuring the NMS, see the NMS user manual.
Verifying the configuration
Verify that the NMS can access and set some MIB variables on the AC.
Shut down and bring up an idle interface on the AC, and verify that the NMS can receive the link traps
from the AC.
- H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module