DS785UM1
18-7
Copyright 2007 Cirrus Logic
Timers
EP93xx User’s Guide
1
8
1
8
18
Timer4ValueLow
Address:
Timer4 - 0x8081_0060 - Read Only
Reset Value:
0x0000_0000
Definition:
This read-only register contains the low word of the time stamp debug timer
(Timer4). When this register is read, the high byte of the Timer4 counter is
saved in the Timer4ValueHigh register.
Bit Descriptions:
Value:
Read Only Low Word of the Timer4 counter.
Timer4ValueHigh
Address:
Timer4 - 0x8081_0064 - Read/Write
Reset Value:
0x0000_0000
Definition:
This is a 9-bit read/write register.
Enable is the only bit that matters during a register write. When set to “1”, the
timer is enabled and begins to count upwards. When set to 0, the debug timer
registers are cleared to all zeros and the timer stops counting
Timer4ValueHigh is a read-only value and contains the high byte of the Timer4
counter. Note that the Timer4ValueLow register must first be read to store the
high byte of the TC4 in Timer4ValueHigh register.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Value
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Value
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RSVD
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RSVD
Enable
Value