2 individual settings dialog box, Block tab, Individual settings dialog box -10 – IDEC High Performance Series User Manual
Page 936
![background image](/manuals/350385/936/background.png)
3 Recipe Settings Dialog Box
18-10
WindO/I-NV2 User’s Manual
3.2 Individual Settings Dialog Box
Use the Individual Settings dialog box to register or edit the recipe settings for the selected channel.
●
Block Tab
The Block tab is used to configure settings that are managed by blocks such as the save destination for the data for
the recipe to use, the Recipe function operation, and the operation trigger.
■
Access to
Selects the save destination for data for the recipe to use when writing values to devices.
■
File Name
Enter the file name of the recipe file to save on the memory card.
The file name that can be set depends on the O/I type.
*1 This is applicable for models with the memory card interface only.
Memory Card
:
Uses a recipe file saved to the memory card.
Requires a memory card with a saved recipe file. For details, refer to “4.2 Creating Recipe Files”
on page 18-17.
Internal Memory:
Uses recipe data saved to internal memory.
Since recipe data is handled as a portion of project data, it may put pressure on the volume of
project data that can be downloaded. One item of recipe data uses 2 bytes when the top device
data type is 16 bits and it uses 4 bytes when the top device data type is 32 bits.
Example: When the top device data type is 16 bits and using 1 block of 16 channels of recipe
data with a data amount of 10
2 x 10 x 1 x 16 = 320 bytes
When the top device data type is 32 bits and using 64 blocks of 16 channels of recipe
data with a data amount of 100
4 x 100 x 64 x 16 = 409.6 kilobytes
HG2G-5F, HG3G/4G:
The default is “RCPn.CSV”. (n: 4 digit sequential number)
To change the file name, enter a new file name. The maximum number is 120 characters
(including the extension).
The file is overwritten when there is a recipe file with the same name on the memory
card.
HG2F/3F/4F:
The file name is “RCPn.CSV”. (n: 4 digit sequential number)
This cannot be changed.