IDEC High Performance Series User Manual
Page 900
3 Operation Log Settings Dialog Box
15-18
WindO/I-NV2 User’s Manual
*1 Advanced mode only
Add Device data to File Name
:
Select this check box to add the bottom three digits of the value of the device configured by (File
Name Device) to the end of the file name for the output data.
(File
Name
Device):
Specifies the word device that is the source for the value to add to the file name. For
the device address configuration procedure, refer to Chapter 2 “5.1 Device Address
Settings” on page 2-67. This option can only be configured when the Add Device data
to File Name check box is selected.
Example: When File Name is "OPLOGA" and the value of the device configured by (File Name
Device) is 123, the file name is "OPLOGA123.CSV".
Add Time Stamp
Selects the format of the output date and time to add to the file name for the output data.
None, YY, YY+MM, YY+MM+DD
The format is YYMMDD (YY: year, MM: month, DD: day).
Example: File Name is "OPLOGA" on September 15 2013
YY:
OPLOGA_13
YY+MM:
OPLOGA_1309
YY+MM+DD:
OPLOGA_130915
Realtime Output
Select this check box to forcibly output the data and save it to file at the desired timing.
(Trigger device):
Specifies the bit device or the bit of the word device to serve as the
condition to forcibly output the data. You can only specify an internal
device. For the device address configuration procedure, refer to Chapter 2
“5.1 Device Address Settings” on page 2-67.
Data is output to file when the trigger device changes from 0 to 1.
The following single-byte characters cannot be used in the file name configured by File Name or Specify
File Name by Value of Device
.
\ / : ; * ? " < > |
• File names that exceed the limits in Specify File Name by Value of Device
and file names
configured with characters that cannot be used are as follows.
- When the values of the source word devices exceeds the maximum number of devices (no NULL), the
text is up to the maximum number of devices from the start.
- When a character that cannot be used is set, the text is up to that character.
- When the first character is a character that cannot be used, the text is that set for File Name.
• The following operations are as follows if the Realtime Output check box
is selected.
- Even if the data is outputted forcibly, the real time output period (3 minute interval) is not reset.
- If the data is outputted but the value of device changes from 0 to 1, then there will be no output to the
data.
- Even when output has finished, the value of device does not automatically change to 0.
• The function to record data operates when Operation Log data is being saved to the memory card.
• For the HG2G-5F and the HG3G/4G, the batch output or real time output status of the Operation Log data
can be checked with the value of HG special relay LSM37. When the data starts to be written to the
memory card, the value of device is 1. When writing is complete, the value is 0.
• The methods to erase Operation Log files saved on the memory card are as follows.
- To erase files during operation using parts, on the Memory Card tab in the Project Settings dialog box,
select the Remove Files stored in Memory Card check box and the All Operation Log data check
box, and then configure the trigger device. Assign that trigger device to a part.
- To erase files with WindO/I-NV2, click Clear on the Online tab, and then click Stored Data in
Memory Card to open the Clear Data dialog box. Select the Operation Log Data check box and click
OK.
- Select the files to erase with the System Menu File Manager, and then press DEL.