IDEC High Performance Series User Manual
Page 1277
![background image](/manuals/350385/1277/background.png)
WindO/I-NV2 User’s Manual
30-33
2 USB Flash Drives
30
External Memory Devices
[AUTORUN] section
■
item (required)
Specify the number of commands used from 1 to 5. The USB Autorun function will fail to execute if a value other than
1 to 5 is specified.
■
button_command
■
button_runall
■
language
[COMMAND] section
■
command (required)
command = PRO_DOWNLOAD
■
src_path (required)
Specify the path (250 or less characters) where the project file is to be downloaded.
Use “A:\” for an SD memory card and “B:\” for a USB flash drive.
command = PRO_UPLOAD
■
dst_path (required)
Specify the path to the folder (250 or less characters) where the uploaded project file will be saved.
Use “A:\” for an SD memory card and “B:\” for a USB flash drive.
Specify whether to enable/disable the execution buttons for [COMMAND_1] to [COMMAND_5].
Enable:
enables the button.
Disable:
disables the button.
If this item is left blank or contains an illegal value, the MICRO/I assumes “Enable”.
Specify whether to enable/disable the execution buttons for Run All.
Enable:
enables the button.
Disable:
disables the button.
If this item is left blank or contains an illegal value, the MICRO/I assumes “Enable”.
Specify the language to use for the button labels and messages.
Japanese:
Shift-JIS
European:
English
Chinese:
GB2312
Taiwanese:
BIG5
Korean
Central European
Baltic
Cyrillic
If this item is left blank or contains an illegal value, the MICRO/I assumes “Japanese”.
Specify the command to execute.
PRO_DOWNLOAD: Download a project file
PRO_UPLOAD:
Upload a project file
LDR_DOWNLOAD: Download a PLC program file
LDR_UPLOAD:
Upload a PLC program file
FILE_COPY:
Copy a file
The items required differ for each command except for the “title” item.