WindO/I-NV2 User’s Manual
3-43
5 User Communication
3
Communic
ation
Example 6
When the trigger condition is satisfied, the value of device is read and data is transmitted in the following order.
When the LDR200 value is 3
Example 7
When the trigger condition is satisfied, the value of device is read and data is transmitted in the following order.
When the LDR200 value is 2
Item
Setting
Conversion Type
No Conversion
Device
LDR100
Use Reference Device
OFF
Storage Method of data
from Lower byte
Number of bytes
2
Words
2
Variable
ON, Device: LDR200
Item
Setting
Conversion Type
No Conversion
Device
LDR100
Use Reference Device
ON, Device: LDR200
Storage Method of data
from Upper byte
Words
2
Variable
OFF
LDR100:
LDR101:
No conversion
Transmission data
34h
12h
78h
Order of transmission
1234h
5678h
12h
34h
56h
78h
Upper
Lower
Value of Device
from Lower byte
2 bytes
Words: 2
LDR200=3
1234h
LDR100:
5678h
LDR101:
2537h
LDR102:
4619h
LDR103:
No conversion
25h
Upper
Lower
Value of Device
37h
46h
19h
LDR200=2
Words: 2
Transmission data
25h
37h
46h
19h
Order of transmission
from Upper byte
2 bytes