4 external interfaces, Serial interface 1, External interfaces -4 – IDEC High Performance Series User Manual
Page 1320: Caution
![background image](/manuals/350385/1320/background.png)
1 HG2G-S/-5S
34-4
WindO/I-NV2 User’s Manual
1.4 External Interfaces
●
Serial Interface 1
• Terminating Resistor Selector Switch (for RS485(422) interface)
When using RS485(422) interface, set the Terminating Resistor Selector Switch to the ON side. This will connect the
internal terminating resistor (100Ω) between RDA and RDB.
CAUTION
• Make sure to turn off the power to the HG2G-S/-5S before wiring each interface or switching the
terminating resistor selector Switch.
• Note that only one of the RS232C or RS485(422) interfaces can be used at one time. Wiring both
interfaces will result in failure of the HG2G-S/-5S. Wire only the interface used.
Interface Specification
RS232C/485(422)
Connector
Detachable Terminal Block 9 pin
Applicable cable
AWG16 to AWG28
Recommended Pressure Terminal
AI 0.25-6 BU
AI 0.34-6 TQ
AI 0.5-8 WH
AI 0.75-8 GY
AI 1-8 RD
(Phoenix Contact)
Tightening Torque
0.22 to 0.25 N·m
No.
Name
I/O
Function
Communication type
1
SD
OUT
Send Data
RS232C
2
RD
IN
Receive Data
3
RS
OUT
Request to Send
4
CS
IN
Clear to Send
5
SG
-
Signal Ground
RS485(422)
6
SDA
OUT
Send Data (+)
7
SDB
OUT
Send Data (-)
8
RDA
IN
Receive Data (+)
9
RDB
IN
Receive Data (-)