7 installation, Operating environment, Ambient temperature – IDEC High Performance Series User Manual
Page 1358: Hg1f installation, Installation -42, Caution
![background image](/manuals/350385/1358/background.png)
3 HG1F
34-42
WindO/I-NV2 User’s Manual
3.7 Installation
●
Operating Environment
For designed performance and safety of the HG1F, do not install the HG1F in the following environments:
• Where dust, briny air, or iron particles exist.
• Where oil or chemical splashes for a long time.
• Where oil mist is filled.
• Where direct sunlight falls on the HG1F.
• Where strong ultraviolet rays fall on the HG1F.
• Where corrosive or combustible gasses exist.
• Where the HG1F is subjected to shocks or vibrations.
• Where condensation occurs due to rapid temperature change.
• Where high-voltage or arc-generating equipment (electromagnetic contactors or circuit protectors) exists in the
vicinity.
●
Ambient Temperature
• Allow sufficient space for ventilation, and install the equipment away from heat sources.
• Allow at least 100mm between the HG1F and walls or other equipment.
• Do not install the HG1F where the ambient temperature exceeds the rated operating ambient temperature range.
When mounting the HG1F in such locations, provide a forced air-cooling fan or air-conditioner to keep the ambient
temperature within the rated temperature range.
• The HG1F is designed to install on a vertical plane so that natural air-cooling is provided. If you install it using any
other orientation, use forced-air cooling, or lower the ambient operating temperature.
●
HG1F Installation
• Make a panel cut-out on the panel with the dimensions shown below.
• Place the HG1F in a panel cut-out and fasten with the attached mounting clips at four places to a torque of 0.12 to
0.15 N•m uniformly.
• When installing the HG1F vertically, make sure that the power input terminal is on the upper side.
CAUTION
• Do not tighten excessively, otherwise the HG1F may warp and cause wrinkle on the display, or
impair the waterproof characteristics.
• If the mounting clips are tightened obliquely to the panel, the HG1F may fall off the panel.
• When installing the HG1F into a panel cut-out, make sure that the gasket is not twisted. Especially
when re-installing, take special care because any twists in the gasket will impair the waterproof
characteristics.
A
B
Unit: mm
A
B
Panel Cut-out
66.0
+1.0
0
137.0
+1.5
0
1.6 to 5.0
Panel
Mounting
Clip
HG1F
Make sure that the
power terminal is on the
upper side.