2 HG2G-5F, HG3G/4G
34-28
WindO/I-NV2 User’s Manual
●
HG2G-5F, HG3G/4G Orientation
The HG2G-5F, HG3G/4G is designed to install on a vertical landscape. If you install it using any other orientation,
confirm the limitations about operating ambient temperature and the use of MICROSmart expansion modules.
*1 When I/O Simultaneous ON Ratio is 50% or less, the Ambient Temperature is 0 to 45°C.
Orientation
Operating Ambient Temperature
w/o expansion modules
w/ expansion modules
Vertical
Landscape
HG2G-5F
0 to 50°C
0 to 40°C
HG3G
0 to 50°C
0 to 45°C
HG4G
0 to 50°C
0 to 50°C
Portrait (Clockwise)
HG2G-5F
0 to 50°C
unavailable
HG3G
0 to 50°C
HG4G
0 to 50°C
Portrait(Counter Clockwise)
HG2G-5F
0 to 45°C
0 to 35°C
HG3G
0 to 45°C
0 to 40°C
HG4G
0 to 50°C
0 to 45°C
Horizontal
HG2G-5F
0 to 45°C
unavailable
HG3G
0 to 45°C
HG4G
0 to 50°C
• When installing the HG2G-5F, HG3G/4G in a diagonal, the limitations are same as a horizontal.
• Confirm the visibility of the display in a final installation.