5 mechanical switches, Mechanical switches -76, Caution – IDEC High Performance Series User Manual
Page 1392
![background image](/manuals/350385/1392/background.png)
6 HG2S
34-76
WindO/I-NV2 User’s Manual
6.5 Mechanical Switches
●
The standard switch layout and functions are described below:
Note: Specify switch operation, contact configuration, and color code in place of * in the Type No.
CAUTION
The emergency stop switch or stop switch and enabling switch incorporated in the HG2S function as
either a category 0 or a category 1 stop in accordance with IEC/EN60204-1. When the switch is used
to shut down power directly, make sure the switching current is within the rated value. For
switching a current over the rated value, use a safety relay or other provision.
No.
Name
Contact
Rating
1
HA1E-V2S2R [Emergency Stop SW(red)]
HA1E-V2S2N-TK2128 [Push Lock Turn Reset SW(gray)]
2NC
24V DC
1A
2
HE1B-M1 [Enabling switch]
1NO (2 pcs)
24V DC 50mA
3 to 6
LA1B-*1T*V* [Pushbutton]
LA1S-**T*V [Selector]
LA1K-**T*V* [Key selector]
1NO or 2NO
24V DC 50mA
7
LA2B-*1T*V* [Pushbutton]
LA2L-*1T*1V* [ill.pushbutton]
LA2P-1TO*V* [Pilot light]
LA1S-**T*V [Selector]
LA1K-**T*V* [Key selector]
LA2F-**T*1V* [ill.selector]
1NO or 2NO
Note
2
5
4
7
3
6
7
1