WindO/I-NV2 User’s Manual
12-51
6 Multi-Command
12
Commands
If Copy Files is selected.
If Download PLC Program is selected.
Source:
Select the source external memory: SD Memory Card or USB Flash Drive.
Path:
Specify the path of the file to be transferred. The maximum number is 247 characters.
Example: Where “Error.wav” is a sound file saved on the root directory of an SD memory
card or USB flash drive:
Error.wav
Destination: Select the destination external memory: SD Memory Card or USB Flash Drive.
Folder Path: Specify the folder path where the file will be transferred. The maximum number is 247
characters.
Example: To save it to the folder “SOUND” inside “HGDATA01” on an SD memory card or
USB flash drive:
HGDATA01\SOUND
• If a file name is specified as the source path name, the specified file is copied.
If a folder name is specified, all of the files and subfolders contained in the folder, and all of the files in
the subfolders, are copied.
• The subfolders can be copied up to five levels.
• To prevent copying the subfolders and the files contained in the subfolders, LSM30 must be set to 1
before executing the copy.
• To stop copying files during the copy operation, write 1 to LSM31. However, it will continue to copy the
file until it is finished then it will stop copying.
Source:
Select the the external memory where the PLC program file to transfer (.ZLD) is stored: SD Memory
Card or USB Flash Drive.
Path:
Specify the path to the PLC program file (.ZLD) to be transferred. The maximum
number is 247 characters.
Example: Where “LDR_PROGRAM.ZLD” is a PLC program file saved in folder
“LDRDATA” of an SD memory card or USB flash drive:
LDRDATA\LDR_PROGRAM.ZLD
Destination: Specify the destination PLC connected to the MICRO/I. The setting varies based on the driver selected
for Host I/F Driver.
OpenNet,MicroSmart,SmartAXIS Pro/Lite(RS232C/485):
Network Number:
Specify the network number of the download destination PLC.
OpenNet,MicroSmart,SmartAXIS Pro/Lite(Ethernet):
Select from the following method:
Specify Station Number:
Specify the station number (0 to 31) of the destination PLC. This
is the station number set in the Project Settings dialog box, on
the Host I/F Network tab. For 1:1 communication, this is 0.
Specify IP Address:
Specify the IP address and port number of the destination PLC.