2 Recipe Function Configuration Procedure
18-6
WindO/I-NV2 User’s Manual
10
Click the Data tab.
The data for the recipe in the amount specified by Number of Data on the Channel tab is configured in Data List.
In Device, the devices are sequentially configured starting from the device address specified by Top Device.
11
Double click the data cell for each number in Data List to enter the value to write to the device.
The value for the device that can be configured varies based on Data Type and Display Type configured on the
Channel tab.
When Read-only is selected under Trigger Setting on the Block tab, entering device values is unnecessary.
12
Click the Block tab.
13
Select the destination to save recipe data to under Access to.
This option is set by block.
■
Memory Card
Use a recipe file saved to the memory card.
■
Internal Memory
Use recipe data saved to internal memory.
If you selected Internal Memory, proceed to step
17
.