Data displa ys – IDEC High Performance Series User Manual
Page 655
![background image](/manuals/350385/655/background.png)
WindO/I-NV2 User’s Manual
10-143
9 Numerical Display
10
Data Displa
ys
■
Data Type
Selects the data type to be handled by the condition formula.
Can only be set if While satisfying the condition is selected as Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.
■
Device
Specifies the bit device or bit of the word device to serve as condition.
Can only be set if While ON or While OFF is selected as Trigger Type.
Click
to display the Device Address Settings dialog box. For the device address configuration procedure, refer
to Chapter 2 “5.1 Device Address Settings” on page 2-67.
■
Condition
Sets the condition formula.
Can only be set if While satisfying the condition is selected as Trigger Type.
Click
to display the Trigger Condition Settings dialog box. For the conditional expression configuration
procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.
■
Comment
Used for entering comments about trigger conditions. Maximum number is 80 characters.
■
While not satisfying the condition
Selects the operation of the Numerical Display when the condition is not satisfied.
*1 HG2G-5F, HG3G/4G only
While ON:
Enables the Numerical Display when the value of device is 1.
Example: When While not satisfying the condition is Not update Numerical data
While OFF:
Enables the Numerical Display when the value of device is 0.
Example: When While not satisfying the condition is Not update Numerical data
While satisfying the condition:
Enables the Numerical Display when the condition is satisfied.
Example: When While not satisfying the condition is Not update Numerical data
Value of Device
1
0
Update
Do not update
Do not update
Do not update
Do not update
Display
Data
99
100
101
102
103
104
105
Update
Update
0
100
100
102
103
103
103
Value of Device
1
0
Update
Do not update
Do not update
Do not update
Display
Data
99
100
101
102
103
104
105
Update
Update
Update
99
99
101
101
101
104
105
Update
Do not update
Do not update
Do not update
Display
Data
99
100
101
102
103
104
105
Update
Update
Update
Condition
Satisfied
Not satisfied
99
99
101
101
101
104
105
Not display Numerical data:
The plate and flange are displayed, but number is not displayed.
Not update Numerical data:
The last updated number is displayed. The number does not change.
Not show Numerical Display
:
Hides the Numerical Display.