Oper ation log function, Windo/i-nv2 user’s manual, 3 operation log settings dialog box – IDEC High Performance Series User Manual
Page 897
![background image](/manuals/350385/897/background.png)
WindO/I-NV2 User’s Manual
15-15
3 Operation Log Settings Dialog Box
15
Oper
ation Log Function
■
Batch
Select this check box to batch output all the sampled data to the memory card.
All the data is saved on the memory card when the trigger device changes from 0 to 1. If a file with the same name
already exists on the memory card, that file is overwritten. The maximum amount of output data is the amount
configured by the data storage area.
*1 Advanced mode only
MICRO/I
OperaƟon Log data
(CSV)
Output to
memory card
Memory Card
OperaƟon Log data
0
1
Trigger Device
Data to be output
(all)
Sampling
Time
User
Screen No.
Event Name
Part Name
Details
Changed to
12/01/2011 12:00:10
-
Base1
Power ON
-
-
-
12/01/2011 12:01:23
User1
Base1
Switch to Base Screen
-
-
Base2
12/01/2011 12:02:45
User1
Base2
Change Users
-
-
User2
12/01/2011 12:03:06
User2
Base2
Change OperaƟon Modes
-
-
System Mode
12/01/2011 12:04:11
User2
Base2
Press buƩons
BitSwitch
-
-
12/01/2011 12:04:11
User2
Base2
Write Data to any Devices
-
LDR 0
55
12/01/2011 12:07:30
User2
Base2
Switch to Base Screen
-
-
Base3
Output stops if there is insufficient free space on the memory card. Memory card error information is stored
in HG special register LSD42.
Trigger Device:
Specifies the bit device that triggers batch output. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
Data is output to file when the trigger device changes from 0 to 1.
File Name:
Enter the file name for the output data or shows the file name.
The default is “OPLOGO.CSV”.
To change the file name, enter a new file name. The maximum number is 120 characters
(including the extension).
Specify File Name by Value of Device
Select this check box to specify the name of the file for the output data with the value of the
device configured by (File Name Device).
(File Name Device):
Specifies the word device that is the source of the data to use as
the file name. The file name is set by reading the values
sequentially from the starting device specified with the file name
device and handling those values as character data up to the
character before NULL (00).
The maximum number of devices is 40 (80 single-byte characters).
You can only specify an internal device. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address
Settings” on page 2-67.
Example: When the device specified by (File Name Device) is LDR100 and the text to set is
"IDEC":
The file name at this time becomes "IDEC.CSV".
LDR100
LDR101
LDR102
(File Name Device)
4844
(Hex)
4543
(Hex)
‘ I ’ ‘D’
‘E’ ‘C’
0000
(Hex)
(NULL)