Lamps – IDEC High Performance Series User Manual
Page 491
![background image](/manuals/350385/491/background.png)
WindO/I-NV2 User’s Manual
9-11
1 Pilot Lamps
9
Lamps
Trigger Type: Selects the condition to display the Pilot Lamp from the following.
Always visible: The Pilot Lamp is always displayed.
While ON:
Displays the Pilot Lamp when the device value is 1.
While OFF:
Displays the Pilot Lamp when the device value is 0.
While satisfying the condition:
Displays the Pilot Lamp when the condition is satisfied.
Data Type:
Selects the type of data handled by the conditional expression for the visible condition.
This option can only be configured if While satisfying the condition is selected for Trigger Type.
For details, refer to Chapter 2 “1.2 Available Data” on page 2-2.
Device:
Specifies the bit device or bit of the word device to serve as the visible condition.
This option can only be configured when While ON or While OFF is selected for Trigger Type.
Click
to display the Device Address Settings dialog box. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-67.
Condition:
Specifies the conditional expression for the visible condition.
This option can only be configured when While satisfying the condition is selected for Trigger
Type.
Click
to display the Trigger Condition Settings dialog box. For the conditional expression
configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-69.
Comment:
Used for entering a comment for the visible condition. The maximum number is 80 characters.
Always show
Pilot Lamp state
1
0
Hide
Show
Hide
Hide
Show
Show
Device value
Pilot Lamp state
1
0
Show
Show
Show
Hide
Hide
Hide
Device value
Pilot Lamp state
Pilot Lamp state
Hide
Hide
Hide
Show
Show
Show
Satisfied
Not satisfied
Condition