WindO/I-NV2 User’s Manual
28-19
1 Project Transfer Function
28
Data T
ransf
er Func
tion
1.6 Precautions
• An error message is displayed if the project data upload or download fails.
For details, refer to Chapter 35 “1.1 Errors Displayed on the Screen” on page 35-1.
• While the project transfer function is running, the MICRO/I stops processing other functions.
• When project data is downloaded using the project transfer function, the HG keep registers and the HG keep relays
are cleared.
• On the HG2G-5F, HG3G/4G, if a project file (ZNV format) exists with the same name in the save destination when
uploading a project file (ZNV format), the file is overwritten with the uploaded file without displaying an overwrite
confirmation message.
• When using the project transfer function, make the project data file name half-width alphanumeric characters.
• While running the project transfer function using a Key Button, Multi-Button, or Multi-Command, if a data transfer
function (project transfer, PLC program transfer, or file copy) is initiated, the only function that will work is the
currently running function. If two or more data transfer functions are configured to a Multi-Button or Multi-
Command, only the data transfer function displayed at the top of the function list on the parts property dialog box
will run.
• When running the project transfer function, the external memory device must have enough free space equivalent
to the size of the ZNV project file. Check that there is sufficient free space on the external memory device that will
be used with the project transfer function. If the device does not have sufficient free space, the project upload or
download may fail.