Trigger condition tab, Lamps – IDEC High Performance Series User Manual
Page 489
![background image](/manuals/350385/489/background.png)
WindO/I-NV2 User’s Manual
9-9
1 Pilot Lamps
9
Lamps
●
Trigger Condition Tab
■
Lightning
The Pilot Lamp is on while the condition is satisfied, and it is off while the condition is not satisfied. The Pilot Lamp
displays the ON graphic when on and it displays the OFF graphic when off.
Example: When Trigger Type is While ON and Device is LM 0
When LM 0 is 0, condition is not satisfied, so Lamp displays OFF graphic.
When LM 0 is 1, condition is satisfied, so Lamp displays OFF graphic.
Trigger Type: Selects the condition to turn on the Pilot Lamp from the following.
While ON:
Turns on the Pilot Lamp when the device value is 1.
LM0:
MICRO/I
0
LM0: 1
Condition
Not satisfied
Condition
Satisfied
Lamp
Displays OFF graphic
Lamp
Displays ON graphic
1
0
Device value
On
Off
Pilot Lamp status
Off
Off
On
On