8.4 Manual control - Functions
■■■■■■■■■■■■■■■■■■■■■■
1616
■■■■■■■■
tiamo 2.4
Gas flow
Inlet
Selection of the carrier gas inlet.
Selection
Pump | Valve
Default value
Pump
Pump
Use of ambient air as carrier gas.
Valve
Use of gas from a compressed gas cylinder.
Flow rate
874
Input range
10 - 150 mL/min
Default value
50 mL/min
Gas type
Gas type of the carrier gas.
Selection
Air | Nitrogen | Other gas
Default value
Air
In the case of the 874 USB Oven Sample Processor,
a gas flow factor has to be specified for the carrier
gas used if Other gas is selected. The gas flow fac-
tor is used for the correct measurement of the flow
rate.
Gas flow factor
Factor for the correct determination of the gas flow. This parameter is dis-
played only if Gas type = Other gas. For air and nitrogen, the appropri-
ate gas flow factor is inserted automatically. The gas flow factor values for
other commonly used carrier gases can be found in the table Gas flow
factors of various gases.
Input range
0.001 - 2.000 (Increment: 0.001)
Default value
1.000
Table 45
Gas flow factors of various gases
Gas type
Gas flow factor
Argon
0.950
Helium
0.300
Air
1.000
- 915 KF Ti-Touch (382 pages)
- 800 Dosino (53 pages)
- 767 Calibrated Reference (23 pages)
- 940 Professional IC Vario ONE/SeS/Prep 2 (54 pages)
- 754 Dialysis Unit (49 pages)
- 815 Robotic Soliprep for LC (76 pages)
- Vision Manual (207 pages)
- tiamo 2.1 Manual (1532 pages)
- 825 Lab Link (37 pages)
- 808 Titrando (70 pages)
- 902 Titrando (52 pages)
- 756 KF Coulometer (163 pages)
- 756 KF Coulometer (162 pages)
- 940 Professional IC Vario ONE/LPG (98 pages)
- 850 Professional IC Anion MCS Prep 3 (152 pages)
- 850 Professional IC Anion MCS Prep 3 (154 pages)
- 904 Titrando (58 pages)
- 850 Professional IC Anion MSM-HC MCS Prep 2 (150 pages)
- 930 Compact IC Flex Oven/ChS/Deg (47 pages)
- 872 Extension Module Liquid handling (64 pages)
- 814 USB Sample Processor (91 pages)
- 814 USB Sample Processor (90 pages)
- 940 Professional IC Vario (43 pages)
- Vision – Tutorial (40 pages)
- 799 GPT Titrino (242 pages)
- 889 IC Sample Center (68 pages)
- 761 Compact IC (228 pages)
- 851 Titrando (100 pages)
- 748 DH Sample Changer (32 pages)
- 940 Professional IC Vario ONE/SeS/HPG (51 pages)
- 896 Professional Detector – Amperometry (62 pages)
- 877 Titrino plus (139 pages)
- 881 Compact IC pro – Anion (129 pages)
- 940 Professional IC Vario ONE/ChS/HPG (112 pages)
- 930 Compact IC Flex Deg (41 pages)
- 840 PC Control 5.0 / Touch Control (351 pages)
- 940 Professional IC Vario ONE/Prep 1 (45 pages)
- 776 Dosimat (42 pages)
- 717 Sample Changer (36 pages)
- 815 Robotic USB Sample Processor XL (114 pages)
- 815 Robotic USB Sample Processor XL (113 pages)
- 940 Professional IC Vario ONE/SeS/PP (126 pages)
- 838 Advanced Sample Processor Installation Instructions (109 pages)
- 700 Dosino (55 pages)
- 719 S Titrino (152 pages)