beautypg.com

LevelOne GTL-2691 User Manual

Page 834

background image

C

HAPTER

25

| SNMP Commands

SNMP Target Host Commands

– 834 –

enable multiple hosts, you must issue a separate snmp-server host

command for each host.

The snmp-server host command is used in conjunction with the

snmp-server enable traps

command. Use the

snmp-server enable traps

command to enable the sending of traps or informs and to specify

which SNMP notifications are sent globally. For a host to receive

notifications, at least one

snmp-server enable traps

command and the

snmp-server host command for that host must be enabled.

Some notification types cannot be controlled with the

snmp-server

enable traps

command. For example, some notification types are

always enabled.

Notifications are issued by the switch as trap messages by default. The

recipient of a trap message does not send a response to the switch.

Traps are therefore not as reliable as inform messages, which include a

request for acknowledgement of receipt. Informs can be used to ensure

that critical information is received by the host. However, note that

informs consume more system resources because they must be kept in

memory until a response is received. Informs also add to network

traffic. You should consider these effects when deciding whether to

issue notifications as traps or informs.

To send an inform to a SNMPv2c host, complete these steps:

1.

Enable the SNMP agent (

page 829

).

2.

Create a view with the required notification messages (

page 839

).

3.

Create a group that includes the required notify view (

page 836

).

4.

Allow the switch to send SNMP traps; i.e., notifications (

page 832

).

5.

Specify the target host that will receive inform messages with the
snmp-server host command as described in this section.

To send an inform to a SNMPv3 host, complete these steps:

1.

Enable the SNMP agent (

page 829

).

2.

Create a local SNMPv3 user to use in the message exchange
process (

page 837

).

3.

Create a view with the required notification messages (

page 839

).

4.

Create a group that includes the required notify view (

page 836

).

5.

Allow the switch to send SNMP traps; i.e., notifications (

page 832

).

6.

Specify the target host that will receive inform messages with the
snmp-server host command as described in this section.

The switch can send SNMP Version 1, 2c or 3 notifications to a host IP

address, depending on the SNMP version that the management station

supports. If the snmp-server host command does not specify the

SNMP version, the default is to send SNMP version 1 notifications.

If you specify an SNMP Version 3 host, then the community string is

interpreted as an SNMP user name. The user name must first be

defined with the

snmp-server user

command. Otherwise, an SNMPv3

group will be automatically created by the snmp-server host

command using the name of the specified community string, and

default settings for the read, write, and notify view.