beautypg.com

Show ethernet cfm md – LevelOne GTL-2691 User Manual

Page 1323

background image

C

HAPTER

44

| CFM Commands

Defining CFM Structures

– 1323 –

This example shows the configuration status for continuity check and

cross-check traps.

Console#show ethernet cfm configuration traps

CC MEP Up Trap :Disabled

CC MEP Down Trap :Disabled

CC Configure Trap :Disabled

CC Loop Trap :Disabled

Cross Check MEP Unknown Trap :Disabled

Cross Check MEP Missing Trap :Disabled

Cross Check MA Up :Disabled

Console#

E

XAMPLE

This example shows the CFM status for port 1.

Console#show ethernet cfm configuration interface ethernet 1/1

Ethernet 1/1 CFM Status:Enabled

Console#

show ethernet cfm

md

This command displays the configured maintenance domains.

S

YNTAX

show ethernet cfm md [level level]

level – Maintenance level. (Range: 0-7)

Table 170: show ethernet cfm configuration traps - display description

Field

Description

CC MEP Up Trap

Sends a trap if a remote MEP is discovered and added to the local

database, the port state of a previously discovered remote MEP

changes, or a CCM is received from a remote MEP which as an

expired entry in the archived database.

CC Mep Down Trap

Sends a trap if this device loses connectivity with a remote MEP, or

connectivity has been restored to a remote MEP which has recovered

from an error condition.

CC Configure Trap

Sends a trap if this device receives a CCM with the same MPID as its

own but with a different source MAC address, indicating that a CFM

configuration error exists.

CC Loop Trap

Sends a trap if this device receives a CCM with the same source MAC

address and MPID as its own, indicating that a forwarding loop

exists.

Cross Check MEP

Unknown Trap

A CCM is received from a MEP that has not been configured as a

DSAP (see the

ethernet cfm mep

command), manually configured as

a remote MEP (see the

mep crosscheck mpid

command), nor learned

through previous CCM messages.

Cross Check MEP

Missing Trap

This device failed to receive three consecutive CCMs from another

MEP in the same MA.

Cross Check MA Up

Generates a trap when all remote MEPs belonging to an MA come up.