Show ethernet cfm, Maintenance-points, Remote crosscheck – LevelOne GTL-2691 User Manual
Page 1338

C
HAPTER
44
| CFM Commands
Cross Check Operations
– 1338 –
These remote MEPs are used in the cross-check operation to verify that
all endpoints in the specified MA are operational.
◆
The cross-check process is disabled by default, and must be manually
started using this command with the enable keyword.
E
XAMPLE
This example enables cross-checking within the specified maintenance
association.
Console#ethernet cfm mep crosscheck enable md voip ma rd
Console#
show ethernet cfm
maintenance-points
remote crosscheck
This command displays information about remote MEPs statically
configured in a cross-check list.
S
YNTAX
show ethernet cfm maintenance-points remote crosscheck
[domain domain-name | mpid mpid]
domain-name – Domain name. (Range: 1-43 alphanumeric
characters)
mpid – Maintenance end point identifier. (Range: 1-8191)
D
EFAULT
S
ETTING
None
C
OMMAND
M
ODE
Privileged Exec
E
XAMPLE
This example shows all remote MEPs statically configured on this device.
Console#show ethernet cfm maintenance-points remote crosscheck
MPID MA Name Level VLAN MEP Up Remote MAC
---- -------------------- ----- ---- ------ ------------------
2 downtown 4 2 Yes 00-0D-54-FC-A2-73
Console#