LevelOne GTL-2691 User Manual
Page 118
C
HAPTER
3
| Using the Web Interface
Navigating the Web Browser Interface
– 118 –
Configure Details
Configures ring parameters
CFM
Connectivity Fault Management
Configure Global
Configures global settings, including administrative status, cross-
check start delay, link trace, and SNMP traps
Configure Interface
Configures administrative status on an interface
Configure MD
Configure Maintenance Domains
Add
Defines a portion of the network for which connectivity faults can
be managed, identified by an MD index, maintenance level, and
the MIP creation method
Configure Details
Configures the archive hold time and fault notification settings
Show
Shows list of configured maintenance domains
Configure MA
Configure Maintenance Associations
Add
Defines a unique CFM service instance, identified by its parent MD,
the MA index, the VLAN assigned to the MA, and the MIP creation
method
Configure Details
Configures detailed settings, including continuity check status and
interval level, cross-check status, and alarm indication signal
parameters
Show
Shows list of configured maintenance associations
Configure MEP
Configures Maintenance End Points
Add
Configures MEPs at the domain boundary to provide management
access for each maintenance association
Show
Shows list of configured maintenance end points
Configure Remote MEP
Configures Remote Maintenance End Points
Add
Configures a static list of remote MEPs for comparison against
the MEPs learned through continuity check messages
Show
Shows list of configured remote maintenance end points
Transmit Link Trace
Sends link trace messages to isolate connectivity faults by
tracing the path through a network to the designated target node
Transmit Loopback
Sends loopback messages to isolate connectivity faults by
requesting a target node to echo the message back to the source
Transmit Delay Measure
Sends periodic delay-measure requests to a specified MEP within a
maintenance association
Show Information
Show Local MEP
Shows the MEPs configured on this device
Show Local MEP Details
Displays detailed CFM information about a specified local MEP in
the continuity check database
Show Local MIP
Shows the MIPs on this device discovered by the CFM protocol
Show Remote MEP
Shows MEPs located on other devices which have been discovered
through continuity check messages, or statically configured in the
MEP database
Show Remote MEP Details
Displays detailed CFM information about a specified remote MEP in
the continuity check database
Show Link Trace Cache
Shows information about link trace operations launched from this
device
Table 6: Switch Main Menu (Continued)
Menu
Description
Page