Figure 22: telnet connection settings – LevelOne GTL-2691 User Manual
Page 154

C
HAPTER
4
| Basic Management Tasks
Telnet Settings
– 154 –
◆
Exec Timeout – Sets the interval that the system waits until user input
is detected. If user input is not detected within the timeout interval, the
current session is terminated. (Range: 60-65535 seconds;
Default: 600 seconds)
◆
Password Threshold – Sets the password intrusion threshold, which
limits the number of failed logon attempts. When the logon attempt
threshold is reached, the system interface becomes silent for a
specified amount of time (set by the Silent Time parameter) before
allowing the next logon attempt. (Range: 1-120; Default: 3 attempts)
◆
Silent Time – Sets the amount of time the management console is
inaccessible after the number of unsuccessful logon attempts has been
exceeded. (Range: 1-65535 seconds; Default: Disabled)
N
OTE
:
The password for the Telnet connection can only be configured
N
OTE
:
Password checking can be enabled or disabled for login to the
console connection (see
). You can select
authentication by a single global password as configured for the password
command, or by passwords set up for specific user-name accounts. The
default is for local passwords configured on the switch.
W
EB
I
NTERFACE
To configure parameters for the console port:
1.
Click System, then Telnet.
2.
Specify the connection parameters as required.
3.
Click Apply
Figure 22: Telnet Connection Settings