| Interface Configuration
Port Configuration
– 173 –
◆
The test takes approximately 5 seconds. The switch displays the results
of the test immediately upon completion, including common cable
failures, as well as the status and approximate length to a fault.
◆
Potential conditions which may be listed by the diagnostics include:
■
OK: Correctly terminated pair
■
Open: Open pair, no link partner
■
Short: Shorted pair
■
Not Supported: This message is displayed for any Gigabit Ethernet
ports linked up at a speed lower than 1000 Mbps, or for any 10G
Ethernet ports.
■
Impedance mismatch: Terminating impedance is not in the
reference range.
◆
Ports are linked down while running cable diagnostics.
P
ARAMETERS
These parameters are displayed:
◆
Port – Switch port identifier. (Range: 1-26)
◆
Test Result – The results include common cable failures, as well as the
status and approximate distance to a fault, or the approximate cable
length if no fault is found.
◆
Accuracy – The accuracy of the reported length to a fault.
(The accuracy displays “0” when no problem is found.)
◆
Last Updated – Shows the last time this port was tested.
◆
Action – Click Test to start cable test for selected port.