beautypg.com

Snmp-server enable traps ethernet cfm cc, Snmp-server enable traps, Ethernet cfm cc – LevelOne GTL-2691 User Manual

Page 1331

background image

C

HAPTER

44

| CFM Commands

Continuity Check Operations

– 1331 –

If a maintenance point receives a CCM with an invalid MEPID or MA

level or an MA level lower than its own, a failure is registered which

indicates a configuration error or cross-connect error (i.e., overlapping

MAs).

E

XAMPLE

This example enables continuity check messages for the specified

maintenance association.

Console(config)#ethernet cfm cc enable md voip ma rd

Console(config)#

snmp-server enable

traps ethernet cfm

cc

This command enables SNMP traps for CFM continuity check events. Use

the no form to disable these traps.

S

YNTAX

[no] snmp-server enable traps ethernet cfm cc [config | loop |

mep-down | mep-up]
configSends a trap if this device receives a CCM with the same

MPID as its own but with a different source MAC address, indicating

that a CFM configuration error exists.
loopSends a trap if this device receives a CCM with the same

source MAC address and MPID as its own, indicating that a

forwarding loop exists.
mep-downSends a trap if this device loses connectivity with a

remote MEP, or connectivity has been restored to a remote MEP

which has recovered from an error condition.
mep-upSends a trap if a remote MEP is discovered and added to

the local database, the port state of a previously discovered remote

MEP changes, or a CCM is received from a remote MEP which as an

expired entry in the archived database.

D

EFAULT

S

ETTING

All continuity checks are enabled.

C

OMMAND

M

ODE

Global Configuration

C

OMMAND

U

SAGE

All mep-up traps are suppressed when cross-checking of MEPs is enabled

because cross-check traps include more detailed status information.