Snmp-server enable traps ethernet cfm cc, Snmp-server enable traps, Ethernet cfm cc – LevelOne GTL-2691 User Manual
Page 1331
C
HAPTER
44
| CFM Commands
Continuity Check Operations
– 1331 –
◆
If a maintenance point receives a CCM with an invalid MEPID or MA
level or an MA level lower than its own, a failure is registered which
indicates a configuration error or cross-connect error (i.e., overlapping
MAs).
E
XAMPLE
This example enables continuity check messages for the specified
maintenance association.
Console(config)#ethernet cfm cc enable md voip ma rd
Console(config)#
snmp-server enable
traps ethernet cfm
cc
This command enables SNMP traps for CFM continuity check events. Use
the no form to disable these traps.
S
YNTAX
[no] snmp-server enable traps ethernet cfm cc [config | loop |
mep-down | mep-up]
config – Sends a trap if this device receives a CCM with the same
MPID as its own but with a different source MAC address, indicating
that a CFM configuration error exists.
loop – Sends a trap if this device receives a CCM with the same
source MAC address and MPID as its own, indicating that a
forwarding loop exists.
mep-down – Sends a trap if this device loses connectivity with a
remote MEP, or connectivity has been restored to a remote MEP
which has recovered from an error condition.
mep-up – Sends a trap if a remote MEP is discovered and added to
the local database, the port state of a previously discovered remote
MEP changes, or a CCM is received from a remote MEP which as an
expired entry in the archived database.
D
EFAULT
S
ETTING
All continuity checks are enabled.
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
All mep-up traps are suppressed when cross-checking of MEPs is enabled
because cross-check traps include more detailed status information.