Cable Diagnostics
– 1014 –
Vcc : 0.00 V
Bias Current : 43.11 mA
TX Power : 605 uW
RX Power : 3 uW
Console#
Cable Diagnostics
test cable-
diagnostics dsp
This command performs cable diagnostics on the specified port to diagnose
any cable faults (short, open, etc.) and report the cable length.
S
YNTAX
test cable-diagnostics dsp interface interface
interface
ethernet unit/port
unit - Stack unit. (Range: 1-8)
port - Port number. (Range: 1-26)
C
OMMAND
M
ODE
Privileged Exec
C
OMMAND
U
SAGE
◆
Cable diagnostics are performed using Digital Signal Processing (DSP)
test methods.
◆
This cable test is only accurate for cables 7 - 140 meters long.
◆
The test takes approximately 5 seconds. The switch displays the results
of the test immediately upon completion, including common cable
failures, as well as the status and approximate length of each cable
pair.
◆
Potential conditions which may be listed by the diagnostics include:
■
OK: Correctly terminated pair
■
Open: Open pair, no link partner
■
Short: Shorted pair
■
Not Supported: This message is displayed for any Gigabit Ethernet
ports linked up at a speed lower than 1000 Mbps, or for any 10G
Ethernet ports.
■
Impedance mismatch: Terminating impedance is not in the
reference range.
◆
Ports are linked down while running cable diagnostics.
E
XAMPLE
Console#test cable-diagnostics dsp interface ethernet 1/1
Cable Diagnostics on interface Ethernet 1/1: