beautypg.com

Cable diagnostics, Test cable- diagnostics dsp, Test cable-diagnostics dsp – LevelOne GTL-2691 User Manual

Page 1014

background image

C

HAPTER

31

| Interface Commands

Cable Diagnostics

– 1014 –

Vcc : 0.00 V

Bias Current : 43.11 mA

TX Power : 605 uW

RX Power : 3 uW

Console#

Cable Diagnostics

test cable-

diagnostics dsp

This command performs cable diagnostics on the specified port to diagnose

any cable faults (short, open, etc.) and report the cable length.

S

YNTAX

test cable-diagnostics dsp interface interface

interface

ethernet unit/port

unit - Stack unit. (Range: 1-8)
port - Port number. (Range: 1-26)

C

OMMAND

M

ODE

Privileged Exec

C

OMMAND

U

SAGE

Cable diagnostics are performed using Digital Signal Processing (DSP)

test methods.

This cable test is only accurate for cables 7 - 140 meters long.

The test takes approximately 5 seconds. The switch displays the results

of the test immediately upon completion, including common cable

failures, as well as the status and approximate length of each cable

pair.

Potential conditions which may be listed by the diagnostics include:

OK: Correctly terminated pair

Open: Open pair, no link partner

Short: Shorted pair

Not Supported: This message is displayed for any Gigabit Ethernet

ports linked up at a speed lower than 1000 Mbps, or for any 10G

Ethernet ports.

Impedance mismatch: Terminating impedance is not in the

reference range.

Ports are linked down while running cable diagnostics.

E

XAMPLE

Console#test cable-diagnostics dsp interface ethernet 1/1

Cable Diagnostics on interface Ethernet 1/1: