beautypg.com

Mep crosscheck mpid – LevelOne GTL-2691 User Manual

Page 1336

background image

C

HAPTER

44

| CFM Commands

Cross Check Operations

– 1336 –

mep-unknownSends a trap if an unconfigured MEP comes up.

D

EFAULT

S

ETTING

All continuity checks are enabled.

C

OMMAND

M

ODE

Global Configuration

C

OMMAND

U

SAGE

For this trap type to function, cross-checking must be enabled on the

required maintenance associations using the

ethernet cfm mep

crosscheck

command.

A mep-missing trap is sent if cross-checking is enabled (with the

ethernet cfm mep crosscheck

command), and no CCM is received for a

remote MEP configured in the static list (with the

mep crosscheck mpid

command).

A mep-unknown trap is sent if cross-checking is enabled, and a CCM is

received from a remote MEP that is not configured in the static list.

A ma-up trap is sent if cross-checking is enabled, and a CCM is received

from all remote MEPs configured in the static list for this maintenance

association.

E

XAMPLE

This example enables SNMP traps for mep-unknown events detected in

cross-check operations.

Console(config)#snmp-server enable traps ethernet cfm crosscheck mep-unknown

Console(config)#

mep crosscheck

mpid

This command statically defines a remote MEP in a maintenance

association. Use the no form to remove a remote MEP.

S

YNTAX

[no] mep crosscheck mpid mpid ma ma-name

mpid – Identifier for a maintenance end point which exists on

another CFM-enabled device within the same MA. (Range: 1-8191)
ma-name – Maintenance association name. (Range: 1-44

alphanumeric characters)

D

EFAULT

S

ETTING

No remote MEPs are configured.

C

OMMAND

M

ODE

CFM Domain Configuration