Displaying details for local meps – LevelOne GTL-2691 User Manual
Page 501

C
HAPTER
14
| Basic Administration Protocols
Connectivity Fault Management
– 501 –
D
ISPLAYING
D
ETAILS
FOR
L
OCAL
MEP
S
Use the Administration > CFM > Show Information (Show Local MEP
Details) page to show detailed CFM information about a local MEP in the
continuity check database.
CLI R
EFERENCES
◆
"show ethernet cfm maintenance-points local detail mep" on page 1326
P
ARAMETERS
These parameters are displayed:
◆
MD Index – Domain index. (Range: 1-65535)
◆
MA Index – MA identifier. (Range: 0-4094)
◆
MEP ID – Maintenance end point identifier. (Range: 1-8191)
◆
MD Name – The maintenance domain for this entry.
◆
MA Name – Maintenance association to which this remote MEP
belongs.
◆
MA Name Format – The format of the Maintenance Association name,
including primary VID, character string, unsigned Integer 16, or
RFC 2865 VPN ID.
◆
Level – Maintenance level of the local maintenance point.
◆
Direction – The direction in which the MEP faces on the Bridge port (up
or down).
◆
Interface – The port to which this MEP is attached.
◆
CC Status – Shows if the MEP will generate CCM messages.
◆
MAC Address – MAC address of the local maintenance point. (If a CCM
for the specified remote MEP has never been received or the local MEP
record times out, the address will be set to the initial value of all Fs.)
◆
Defect Condition – Shows the defect detected on the MEP.
◆
Received RDI – Receive status of remote defect indication (RDI)
messages on the MEP.
◆
AIS Status – Shows if MEPs within the specified MA are enabled to
send frames with AIS information following detection of defect
conditions.
◆
AIS Period – The interval at which AIS information is sent.
◆
AIS Transmit Level – The maintenance level at which AIS information
will be sent for the specified MEP.