| Basic Administration Protocols

Connectivity Fault Management

– 500 –

D

ISPLAYING

L

OCAL

MEP

S

Use the Administration > CFM > Show Information (Show Local MEP) page

to show information for the MEPs configured on this device.

CLI R

EFERENCES

"show ethernet cfm maintenance-points local" on page 1325

P

ARAMETERS

These parameters are displayed:

MEP ID – Maintenance end point identifier.

MD Name – Maintenance domain name.

Level – Authorized maintenance level for this domain.

Direction – Direction in which the MEP communicates CFM messages:

Down indicates that the MEP is facing away from the switch, and

transmits CFM messages towards, and receives them from, the

direction of the physical medium.

Up indicates that the MEP faces inward toward the switch cross-

connect matrix, and transmits CFM messages towards, and receives

them from, the direction of the internal bridge relay mechanism.

Primary VLAN – Service VLAN ID.

Interface – Physical interface of this entry (either a port or trunk).

CC Status – Shows administrative status of CCMs.

MAC Address – MAC address of this MEP entry.

W

EB

I

NTERFACE

To show information for the MEPs configured on this device:

1.

Click Administration, CFM.

2.

Select Show Information from the Step list.

3.

Select Show Local MEP from the Action list.