Displaying local meps, Figure 281: showing information on local meps – LevelOne GTL-2691 User Manual
Page 500
C
HAPTER
14
| Basic Administration Protocols
Connectivity Fault Management
– 500 –
D
ISPLAYING
L
OCAL
MEP
S
Use the Administration > CFM > Show Information (Show Local MEP) page
to show information for the MEPs configured on this device.
CLI R
EFERENCES
◆
"show ethernet cfm maintenance-points local" on page 1325
P
ARAMETERS
These parameters are displayed:
◆
MEP ID – Maintenance end point identifier.
◆
MD Name – Maintenance domain name.
◆
Level – Authorized maintenance level for this domain.
◆
Direction – Direction in which the MEP communicates CFM messages:
■
Down indicates that the MEP is facing away from the switch, and
transmits CFM messages towards, and receives them from, the
direction of the physical medium.
■
Up indicates that the MEP faces inward toward the switch cross-
connect matrix, and transmits CFM messages towards, and receives
them from, the direction of the internal bridge relay mechanism.
◆
Primary VLAN – Service VLAN ID.
◆
Interface – Physical interface of this entry (either a port or trunk).
◆
CC Status – Shows administrative status of CCMs.
◆
MAC Address – MAC address of this MEP entry.
W
EB
I
NTERFACE
To show information for the MEPs configured on this device:
1.
Click Administration, CFM.
2.
Select Show Information from the Step list.
3.
Select Show Local MEP from the Action list.
Figure 281: Showing Information on Local MEPs