beautypg.com

Fan control, Fan-speed force-full, Table 48: fan control commands – LevelOne GTL-2691 User Manual

Page 777

background image

C

HAPTER

24

| System Management Commands

Fan Control

– 777 –

between the two end nodes must be able to accept the extended frame

size. And for half-duplex connections, all devices in the collision domain

would need to support jumbo frames.

This command globally enables support for jumbo frames on all Gigabit

and 10 Gigabit ports and trunks. To set the MTU for a specific interface,

enable jumbo frames and use the

switchport mtu

command to specify

the required size of the MTU.

The current setting for jumbo frames can be displayed with the

show

system

command.

E

XAMPLE

Console(config)#jumbo frame

Console(config)#

R

ELATED

C

OMMANDS

switchport mtu (1005)

show system (773)

show ipv6 mtu (1418)

F

AN

C

ONTROL

This section describes the command used to force fan speed.

fan-speed force-full

This command sets all fans to full speed. Use the no form to reset the fans

to normal operating speed.

S

YNTAX

[no] fan-speed force-full

D

EFAULT

S

ETTING

Normal speed

C

OMMAND

M

ODE

Global Configuration

E

XAMPLE

Console(config)#fan-speed force-full

Console(config)#

Table 48: Fan Control Commands

Command

Function

Mode

fan-speed force-full

Forces fans to full speed

GC

show system

Shows if full fan speed is enabled

NE, PE