Defining cfm structures, Ethernet cfm ais level – LevelOne GTL-2691 User Manual
Page 1312
C
HAPTER
44
| CFM Commands
Defining CFM Structures
– 1312 –
5.
Enable CFM globally on the switch with the
command.
6.
Enable CFM on the local MEPs with the
command.
7.
Enable continuity check operations with the
command.
8.
Enable cross-check operations with the
command.
Other configuration changes may be required for your particular
environment, such as adjusting the interval at which continuity check
messages are sent (
), or setting the start-up delay for the cross-
check operation (
). You can also enable SNMP traps for events
discovered by continuity check messages (
) or cross-check
messages (
).
Defining CFM Structures
ethernet cfm ais
level
This command configures the maintenance level at which Alarm Indication
Signal (AIS) information will be sent within the specified MA. Use the no
form restore the default setting.
S
YNTAX
ethernet cfm ais level level-id md domain-name ma ma-name
no ethernet cfm ais level md domain-name ma ma-name
level-id – Maintenance level at which AIS information will be sent.
(Range: 0-7)
domain-name – Domain name. (Range: 1-43 alphanumeric
characters)
ma-name – Maintenance association name. (Range: 1-44
alphanumeric characters)
D
EFAULT
S
ETTING
Level 0
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
The configured AIS level must be higher than the maintenance level of the
domain containing the specified MA.